Product Parameter |
Parameter Description |
Size |
260Lx54.7Wx29.6H(mm) |
Armature Plate Dimension |
190Lx45Wx13.2H(mm) |
Input Voltage |
DC12V(Default); DC24V(Adjustable) |
Current |
12V/500mA(±10%);24V/250mA(±10%) |
LED |
Red shows locked ;Green shows unlocked |
Signal Output |
Lock signal(NO/NC/COM) |
Holding Force |
350kg(800Lbs)±10% direct pull |
Operating temperature |
-30℃~+66℃ (-22~151F) |
Operating humidity |
0~95% relative humidity |
Surface temperature |
Within 20℃ above ambient temperature |
Salt spray test |
240-hour exposure (National laboratory report) |
Holding force after salt spray test |
Holding force attenuation within 5% after 240 hours of salt spray test |
Durability |
Passed 1 million tests |
Holding force after durability test |
Holding force attenuation within 5% after 1 million durability tests |
Dynamic impact test |
45J hammer continuous impact 5 times |
Residual magnetism test |
Demagnetization and unlocking within 0.5 seconds |
Overvoltage test |
125% overload normal operation |
Undervoltage test |
85% input voltage pull force test |
Housing treatment |
Anodized hard plating (500-hour salt spray test report) |
Flame-retardant lock body |
Potting with flame-retardant resin (grade :V-0) |
Suitable |
Wooden door , Glass door ,Metal door , Fireproof door |
Weight |
2.7KG |
Certification |
MA CE-EMC CE-LVD FCC RoHS REACH WEEE EN1634-1 TUV |